| 1/2〞Aluminum RF coaxial cable |
 |
| Type Type No. |
Standard cable HCAALY-50-12
Fire-retardant cable HCAALYZ-50-12 |
| Construction |
Inner
conductor |
Material |
CCA |
| Diameter(mm) |
4.8±0.05 |
| Insulation |
Material |
Foamed PE |
| Diameter(mm) |
12.10±0.20 |
Outer
conductor |
Material |
Annular
corrugated
Aluminum tube |
| Diameter(mm) |
13.9±0.20 |
| Jacket |
Material |
LLDPE or fire-retardant PE |
| Min.thickness(mm) |
>0.8 |
| Diameter(mm) |
27.70±0.30 |
| Mechnical Characteristics |
| Bending radius(mm) |
Single bend |
70 |
| Repeated bend |
125 |
| Tensile strength(N) |
1130 |
| Cable weight(kg/km) |
2.0 |
| Recommended temperature(℃) |
Storage |
-70~+85 |
| Installation |
-40~+60 |
| Operating |
-55~+85 |
|
| Products meet the RoHS requirement, and according to the requirements of RoHS, you can see the RoHS mark on the outside package. |
|
| Electrical Characteristics |
| Inner conductor DC resistance(Ω/km) |
1.48 |
| Outer conductor DC resistance(Ω/km) |
3.00 |
| Characteristic impedance(Ω) |
50±1 |
| Capacitance(p F/m) |
75 |
| Velocity(%) |
88 |
| Dielectric strength(KV) |
6.0 |
| Insulation resistance(MΩ/km) |
>1×104 |
| Peak power rating(KV) |
40 |
| Shielding attenuation,(dB) |
>>120 |
| Cut-off frequency(GHz) |
8.8 |
| Attenuation |
Frequency
(MHz) |
Attenuation
(@20℃,d B/100m) |
| 150 |
2.90 |
| 450 |
5.23 |
| 800 |
7.10 |
| 900 |
7.57 |
| 1000 |
8.00 |
| 1500 |
10.00 |
| 1800 |
11.10 |
| 2000 |
11.77 |
| 2200 |
12.32 |
| 2500 |
13.30 |
| 3000 |
14.74 |
| VSWR |
| 800MHz~1000MHz |
1.15 |
| 1700MHz~2200MHz |
1.15 |
| 5MHz~3000MHz |
1.25 |
|
Note:
For fire-retardant jackter cable,recommended temperature:
Storage:-30℃~+80℃
Installation:-25℃~+60℃
Operating temperature:-30℃~+80℃ |
|